HUAWEI SUN2000-6KTL-M1 Inverter High Current Version
3-phase WR with 6.600VA power output
2 independent MPP trackers
1 battery connection (Plug & Play) for LUNA2000 ESS 5-15kWh
Efficiency up to 98.6%
Compatible with module optimizer
Communication via WLAN / Ethernet & 4G/LTE*
Free system monitoring with FusionSolar
RS485 for Smart Power Sensor & LUNA2000 ESS 5-15kWh
Integrated AC and DC overvoltage protection TYPE II
Integrated PID recovery
Convection cooling
Protection class IP65

Gewicht 17 kg
Größe 53 × 47 × 15 cm

Huawei SUN2000-6KTL-M1 High Current Version – General Data
Betriebstemperaturbereich: -25 ~ +60 °C
Relative Betriebsfeuchtigkeit: 0 % RH~100 % RH
Betriebshöhe: 0 – 4.000 m (Derating > 2.000 m)
Kühlung: Konvektionskühlung
Anzeige: LED – Anzeige
Kommunikation: RS485, WLAN, Ethernet über Smart Dongle-WLAN-FE; 4G/3G/2G über Smart Dongle 4G (optional)
Gewicht (inkl. Befestigungswinkel): 17 Kg
Abmessungen (inkl. Befestigungswinkel): 525 x 470 x 146.5 mm
Schutzart: IP65
Energieverbrauch nachts: < 5,5 W (<10 W, wenn die PID-Wiederherstellungsfunktion aktiviert ist) Huawei SUN2000-6KTL-M1 High Current Version - Input (DC) Recommended maximum PV power1: 9,000 Wp Max. Input voltage2: 1,100 V Operating voltage range3 : 140 V ~ 980 V Starting voltage : 200 V Rated input voltage : 600 V Max. Input current per MPPT: 13.5 A Max. Short circuit current: 19.5 A Number of MPP trackers: 2 Max. Number of inputs per MPPT: 1 Huawei SUN2000-6KTL-M1 High Current Version - Input (DC Battery) Compatible battery: HUAWEI Smart String ESS 5kWh - 30kWh Operating voltage range: 600 V ~ 980 V Maximum operating current: 16.7 A Maximum charging power: 10,000 W Maximum discharging power: 6,600 W Huawei SUN2000-6KTL-M1 High Current Version - Output (On Grid) Mains connection: 3-phase Rated power: 6,000 W Maximum apparent power: 6,600 VA Rated output voltage: 220 Vac / 380 Vac, 230 Vac / 400 Vac, 3W / N+PE AC mains frequency: 50 Hz / 60 Hz Maximum output current: 10.1 A Adjustable power factor: 0.8 cap. ... 0.8 ind. Total harmonic distortion (THD): ≤ 3%. Huawei SUN2000-6KTL-M1 High Current Version - Output (Backup Power via Backup Box-B1) Maximum apparent power: 3,300 VA Rated output voltage: 220 V / 230 V Maximum output current: 15 A Adjustable power factor: 0.8 kap. ... 0.8 ind. Huawei SUN2000-6KTL-M1 High Current Version - Protection and function DC load break switch: Yes Islanding detection: Yes DC reverse polarity protection: Yes Insulation monitoring: Yes DC overvoltage protection: Yes, compatible with protection type TYPE II according to EN / IEC 61643-11 AC overvoltage protection: Yes, compatible with protection type TYPE II according to EN / IEC 61643-11 Fault current monitoring: Yes AC overcurrent protection: Yes AC short-circuit protection: Yes Arc detection: Yes Inputs for ripple control receivers: Yes Integrated PID recovery: Yes Battery charging from mains possible: Yes Huawei SUN2000-6KTL-M1 High Current Version - Module Optimiser DC MBUS compatible optimizer: SUN2000-450W-P SUN2000-450W-P2 SUN2000-600W-P Huawei SUN2000-6KTL-M1 High Current Version - Standards Compliance (others available on request) Safety standards: EN/IEC 62109-1, EN/IEC 62109-2, IEC 62116 Mains connection standards: G98, G99, EN 50438, CEI 0-21, VDE-AR-N-4105, AS 4777, C10/11, ABNT, UTE C15-712, RD 1699, TOR Erzeuger Typ A, NRS 097-2-1, IEC61727, IEC62116, DEWA Huawei SUN2000-6KTL-M1 High Current Version - included in delivery PV Connector Battery Connector AC Connector Signal Cable Connector Bracket WLAN-FE-Dongle Huawei SUN2000-6KTL-M1 High Current Version - Notes and Explanations 1 The maximum PV input power of the inverter is 20,000Wp when long strings are designed and fully connected to the SUN2000-450-P power optimizers. 2 The maximum input voltage is the upper limit of the DC voltage. Any higher input DC voltage would likely damage the inverter. 3 Any DC input voltage above the operating voltage range may cause faulty operation.